K1 Dual Port Smart Charger Instruction Manual
402K1000001
Under the advanced setting menu, select the system setting into the system setting menu as follows:
System Setting Menu
Min. input voltage protection: 10~24V
all tasks in operation will be stopped at once and hint warning of low voltage, when the input voltage is lower than the input voltage
as set up. It will protect the battery from being discharged when using battery pack as power supply.
Max. input power setting: 100~550W
if the input power is smaller than the max working power (550W) , please set up the parameter as the actual output power as max input,
to protect the input power and enable the charger to work stable.
Volume
There are 4 options of High Mid Low and Off for volume setting.When the setting is OFF,
it will turn off the operation sound,but not the warning error beep.
Split screen
There are 3 options of 60 seconds,30 seconds and OFF for automatic split screen setting.
You can choose to switch the display of the main interface from the single-channel parameter interface to
Dual channel (split screen) parameter interface. You can also select "Off" to turn off the automatic split screen function.
Self-test
When all batteries on CH1 and CH2 port are not connected, please select this option to self-test task manually.
Calibration
the input voltage, output voltage and balance voltage of the charger can be calibrated with this task.
*All product photos, statements and literature are for reference only. For up-to-date information, please visit our official web www.isdt.co
SHENZHEN ISD TECHNOLOGY CO. LTD
ISDT reserves the right of final explanation and revision for the terms.