Warnings and Safety Tips The following safety tips are essentially important. Please strictly follow the manual’s instructions in operation to guarantee safety. Improper operation or incorrect working parameter settings may cause damages to the charger and battery and/or result to a fire. Do not use the charger in an unattended manner; in case of any functional abnormity, please stop using it and refer to the manual.
Product Parameters and Characteristics Thank you for purchasing the ISDT Q6 Plus Charger. This Manual will guide you how to use Q6 Plus and its important functions. You can know more about relevant information of IDST products by following this link: www.isdt.co 2 1 Guide For the Connection 3 of Balanced Port 7 4 6 5 1. 2.4”IPS Display 5. Speed Shuttle key 3. Update Port 7. Battery Port 2. Power Input 4. Opto- sensor 6.
Product Parameters and Characteristics 80MM 80MM Specifications: 33.
Default Battery Type of Charger and Task Parameters NiCd/NiMH Pd LiFe Lilon LiPo LiHv Rated Voltage 1.20V 2.00V 3.20V 3.60V 3.70V 3.80V Full Charge Voltage 1.40V 2.46V 3.65V 4.10V 4.20V 4.35V Storage Voltage Not supported Not supported 3.30V 3.70V 3.80V 3.85V Discharge Voltage 1.10V 1.90V 2.90V 3.20V 3.30V 3.40V Pre-charge Voltage 0.90V 1.80V 2.60V 2.90V 3.00V 3.
How to Confirm Charging Current It is very important to know the maximum charging current of the battery as excessive current could influence the life span of battery and/or cause damages. In addition, excessive current can cause heating and/or explosion of the battery during the charging process. The charging and discharging capacity of battery is usually marked with C value. Multiplying the charging C value and battery capacity equals to the maximum charging current supported by the battery.
Task Setting Connect the charger to the power supply and wait for the system to complete the self testing. Connect the battery to the charger under standby interface, and short press the shuttle key to make the task setting menu to pop up.
Task Setting The working mode of the charger is series charging; you must therefore connect it to the output line of the battery while charging. For a lithium battery, it is highly suggested that the balanced interface should be connected to carry out balanced charging to accurately monitor the voltage of each cell and balance the ones with bad consistency.
Task Setting Since the way of internal resistance measurement varies, it cannot be realized to measure the absolute value as professional internal resistance tester does. Therefore, the internal resistance value can only be referred to when conducting horizontal comparisons, such as judging the consistency of the cells’ performance or making comparisons of the performance of different cells.
Working Parameters Display Task operation time Present current Device Name Battery percentage Capacity charged Battery type – string number Current task status Cell voltage Rotating the shuttle key during operation can switch the displayed information in the lower half of the screen, which are cell voltage, cell internal resistance and working parameter. The cell voltage and internal resistance can only be displayed in the mode of balance charging (3 minutes).
Working Parameters Display
Long press the shuttle key in standby interface to make the system default menu pop up, and the items are as follows: Max Input Power Min Input Voltage Backlight Volume Limited between 50 - 330 W Limited between 7 - 32 V Three gears: high, medium, low Three gears: high, medium, low; and off About See system software information Save Save altered system default items Cancel Cancel all alteration and exit system default menu Max input power limitation: if the input power fails to reach the max working
Error in power on self-testing: the charger can automatically carry out a self-testing when connected to a power supply. A self-testing error warning sound should be heard when the charger is connected to the battery; power on after removing the battery for 5 minutes.
SC-620 smart charger conforms to relevant EC command and relevant commands in B: 2010, CHAPTER 15, FCC Testing standards Result EN 55014-1:2006+ A1:2009+A2:2011 YES EN 55014-2:1997+ A1:2001+A2:2008 YES For electronic products with this marking in their manuals, please separately dispose them with family garbage. When a charger gets spoilt and cannot be used anymore, please take it to a nearby garbage station or recycle center.
TM Shenzhen ISD Technology CO.,LTD Address:Rm 302, Building 11th, Pingshan Creative Industry Park, Pingshan 1 Road, Nanshan District, Shenzhen, PRC Changes in specifications and data will not be further noticed. Email:hi@isdt.