condensaon that may have formed, both inside the unit and in the external water
collecon tray. The natural defrosng me can vary from a few minutes to several
hours. In the winterme and when the refrigerator is shut o, the door should be le
slightly ajar for venlaon and all power disconnected.
Classic model venlaon:
Classic models are equipped with a handle with special stopper designed to leave the
door in posion for venlaon.
To set the door in the venlaon posion, use a knife or coin to release the stopper
(Fig. 5). Once the stopper has been released, hook the door in the venlaon
posion.
Elegance model venlaon:
Elegance models are equipped with a special door stopper system to set the door in
the venlaon posion inserted in the top of the refrigerator.
To set the door in venlaon posion, push the door stopper toward the right to the
venlaon posion “--> TO VENT” (Fig. 6).
3.1 Low voltage protecon
In order to prevent excessive baery depleon, a protecon device shuts o the
compressor in case of insucient voltage and turns it back on when the voltage in
the system increases aer the baeries have been charged.
System Voltage Shut-down
Voltage
Minimum Operang
Voltage
12V 9.6 (10.4) V 10.9 (11.7) V
24V 21.3 (22.8) V 22.7 (24.2) V
If the bridge is removed between C and P, the values indicated in the parentheses are
valid.
WARNINGS: Before switching on the unit, always make sure that the
baeries are in opmal condion.