Product Manual
User Manual
49
4.5 Electrical Connecons
• In order connect the unit to the vehicle's electrical system, proceed as follows:
• Before turning on the appliance, check to make sure that the voltage of the
electrical system and/or baery complies with that which is indicated on the
unit’s data plate.
• Connect the refrigerator directly to the baery or to the relave main switch and
make sure that the system is equipped with an electric device that’s capable of
protecng the circuit against possible overcurrents.
If the power supply voltage is dierent from 12/24Vdc, install a ΔI 0.03A dierenal
circuit breaker. Avoid connecng the unit via the vehicle's control panel as this could
result in voltage drops.
• Insert a fuse upstream from the refrigerator (see the table below). Connect the
red wire to the electrical system’s posive terminal, and connect the black wire
the negave terminal. Use a pressed lug terminal that’s suitable for the cable’s
size.
• A separate switch that simultaneously disconnects the power cables must be
installed upstream from the refrigerator. Check to make sure that the installed
switch supports the corresponding load indicated in the table below.
Models 12Vdc 24Vdc
CR36, CR40CUBE, CR42, CR49, CR63F, CR65, CR65F, CR85,
CR90F, CR90BIG, CR100, CR130, CR130D (Elegance models
included) 15A 7.5A
CR195 25A 12.5A
CR200 20A 10A
WARNING! If there is a baery charger, it must be connected to the baery
and never directly to the refrigerator.
All wiring diagrams can be found at the end of the manual.