Product Manual

User Manual
50
4.6 Size of the electrical cables
Always use cables of a suitable cross-secon. The minimum cross-secons are listed
in the table below:
Cross-secon in
mm²
AWG secon
Max 12 V cable length
m/
Max 24V cable length
m/
BD1.4F / BD35F / BD50F
2.5 13 2.5/8 5/16
4 11 4/13 8/26
6 9 6/19 12/39
10 7 10/33 20/66
BD80F
6 9 2,5/8 5/16
10 7 4/13 8/26
4.7 Internal lighng
In order to replace the LED light bulb, slide the lighng unit’s glass down using the
appropriate lever. Replace the light bulb and to return the lighng unit to its original
state (Fig. 4).
Only use original Indel Webasto Marine Srl spare parts.