Product Manual

User Manual
58
CR 130 527 746 505 40 531:751 /:/:10:/
CR 130 ELEGANCE 528 746 505 50 530:751 /:/:9:/
CR 130 DRINK 527 746 520 40 531:751 /:/:10:/
CR 195 550 1345 580 / 555:1350 35:35:30:/
CR 200 730 880 620 / 735:890 20:20:20:/
CR 36 INOX 453 255 580+135(1) / 458:260 30:30:30:30 REM
CR 63F INOX 495 620 555 / 500:625 20:20:20:/
CR 65F INOX 545 610 580 / 550:620 20:20:20:/
CR 90F INOX 545 743 555 / 550:748 20:20:20:/
CR 130D INOX 545 743 560 / 550:748 20:20:20:/
CR 160 INOX 626 870 610 / 630:870 20:20:20:/
CR 195 INOX 545 1345 580 / 550:1350 20:20:20:/
CR 200 INOX 730 868 620 / 735:873 20:20:20:/
CR 320 INOX 628 1790 610 / 630:1790 20:20:20:/
REM: the product is provided with the possibility of moving the compressor unit based on the length of
the supplied hoses.
Note(1) depth that takes into account the curvature of the tube at the point of tube exit from the trunk
ā€œDā€=35mm
Note(2) depth that takes into account the curvature of the tube in the case of remote control ā€œDā€=80mm
(the tube is very rigid)
FOR AC/DC VERSIONS, KEEP IN MIND THAT, DUE TO LACK OF SPACE, DEPTHS EXCEEDING 50 mm WILL
HAVE TO BE EVALUATED ON A CASE BY CASE BASIS.
AS PER REGULATIONS AND FOR PROPER OPERATION, THE WALLS OUTSIDE OF THE REGRIGERATOR
SHOULD BE SET AT THE FOLLOWING DISTANCES FROM THE INTERNAL WALLS OF THE UNIT: 20mm ON
WALLS WHERE THE COMPRESSOR IS NOT PRESENT AND 50MM ON THE WALLS WHERE THE COMPRESSOR
IS PRESENT. IF THESE RULES CANNOT COMPLIED WITH, THE MINIMUM DISTANCE MEASUREMENTS MUST
BE 5mm AND THE MATERIALS WITH WHICH THE WALLS ARE MADE MUST BE EXPLOSION PROOF.