Important User Information The user must adhere to the installation specifications described in this Product Installation and Operation Manual (hereinafter referred to as the "instruction manual"). iSpring is not responsible for damage, loss, or injury resulting from neglect, improper maintenance, or unauthorized modification of products. ● The unit should be placed only on flat surfaces. Do not mount on a wall. ● This product is designed for residential use only.
Reset filter: Filter life indicating lights remain white and started to blink in white when the corresponded filter life has less than 10% remaining, then turn red when the filter needs to be replaced ASAP. Filter life indicator must be reset each time the filter is replaced. To replace the filter, 1. Shut off the water supply and turn on the faucet to drain the remaining water in the system. 2. Unplug the power adapter. 3. Press the button on the filter to release the filter lock.
▪ Malfunction Inspection Fault Codes Type E1: Timeout protection for continuous pump operation. Water Dispensing >30 min. E2: Water leakage protection. Malfunction No water output Reminder Solution "On" Light Faucet Light Buzzer Flashing Red Flashing Red The buzzer will sound for 1 minute. Shut off the faucet, then reconnect the power supply. Solid Red Flashing Red The buzzer will sound for 1 minute. Identify leakage source. Once corrected, reconnect the power supply.