iSpring Water Systems WF SERIES INSTALLATION INSTRUCTIONS & OPERATION MANUAL Model WF150K iSpring Whole House Central Water Filter If you have any questions or concerns when installing, operating, or maintaining your Whole House Central Water Filtration System, call us: 1-678-261-7611 or visit www.ispringfilter.com When you call, please be prepared to provide the model of your product. Warranted by (Ver.
Table of Contents Page Product Operation & Specifications .............................................................................................3 Before You Start...........................................................................................................................4 Optional Parts .......................................................................................................................... 5-7 How a Central Water Filtration System Works ................................
Product Operation & Specifications While testing was performed under standard laboratory conditions, actual performance of the system may vary based on local water conditions. SPECIFICATIONS Hydrostatic Test Pressure Working Pressure Limits (minimum / maximum) Water Temperature Limits (minimum / maximum) Riser Pipe Diameter Required Electrical Adapter Model WF150K 350 psi (24.15 bar) 20 ~ 125 psi (1.38 ~ 8.62 bar) 33.8 ~ 102.2 °F (1 ~ 39 °C) 1.050 inch (26.
Before You Start Warning This machine can only use 120V / 60Hz unidirectional AC power. Do not place anything on the power cord, and set the unit where the power cord will not be stepped on or tripped over. Do not overload sockets or extension cords. Otherwise, it may cause overload or electric shock. If there is smoke, abnormal odor or abnormal noise in this machine, please unplug the power plug of this machine, these conditions may cause fire or electric shock.
Optional Parts 1. Inlet/Outlet Screw Standards: 2. Inlet/Outlet Screw Adaptor: Connect Screw NPT6M 3.
Optional Parts 4. Drain line Flow Controls(DLFC) and Injector: Different Size DLFC is available for different tanks as follows: Replacing Injector and DLFC according to the following picture.
Optional Parts 5.
How a Central Water Filtration System Works (1) Product Functions and Features The whole house central water filtration series products, use imported filter material KDF and high-quality coconut shell activated carbon to purify further municipal tap water, which can effectively reduce the odor, residual chlorine, and organic content in tap water. The automatic backwashing device of the system can loosen and wash the filter material and remove pollutants from the sewage pipe.
How a Central Water Filtration System Works (d) Water Purification Process: Municipal Tap WaterActivated CarbonAlloy Filter MediaPurified Water (2) Structure Automatic multi-way electronic control valve Made of high-strength polyphenylene ether (PPE) with glass fiber, hygienic, reliable and durable Corrosion resistance and rust-free Structural science and well-designed Filter Using high-purity copper-zinc alloy filter Polyethylene (PE) liner fiberglass tank Made of synthetic materials, lig
How a Central Water Filtration System Works Main Functions Daily Reserve Backwash Override/Rinse Override Forced Regeneration Smart Clean Multi-Language Function: English , Spanish and other language are available to meet the different country. Continuous water monitoring / Continuous no water monitoring Auto-locking: All keys will be locked after 3 minutes during the stand-by status. Press and hold “MENU” key for 3 seconds to unlock. Please refer to the programming manual for more details.
Installation Requirements (1) Equipment Installation Conditions The installation location should be well ventilated and protected against wind and rain. Avoid direct sunlight and radiation from other heat sources. The relative humidity of the installation and use environment does not exceed 75% RH. Equipment and pipes installed outdoors should be insulated and frost-proofed. The inlet water must meet the water quality standard of municipal tap water. The water pressure is 0.14 mPa - 0.
Installation Requirements damage to the water pipe or the product due to the pressure of the pipeline after longterm use. There must be a space (about 10 cm) between the outlet of the sewage pipe and the sewage to prevent the sewage from flowing back to the product; the underground sewage pipe should be 30 cm higher than the ground, and the sewage pipe should be fixed on the sewage pipe (do not Insert the sewage pipe directly into the sewage in the sewer or sewer).
Installation Instructions (1) Precautions Before Commissioning Check whether the water inlet pipe and sewage pipe are connected as required. All piping connections comply with relevant national standards. Fix the sewage pipe on the sewer pipe, and do not insert it directly into the sewer pipe. A gap of 100 mm shall be maintained with the bottom of the sewer pipe. Check whether the pressure of the water source is within the range of 0.14 mPa - 0.35 mPa.
Installation Instructions One machine and the accessories: ① power adapter (white box, 1 pcs.) (adhered to the base), ② sewage pipe (translucent pipe, 1 pcs.), ③ stainless steel braided hose (NPT6M connector, 2pcs.), ④ stainless steel clamps (in the PE bag, 1 pcs.), ⑤ hex key (in the PE bag, 1 pcs.). (a) The water inlet is connected to the stainless steel braided hose, and the other end is connected to the water inlet channel.
Installation Instructions (4) General Valve Installation (a) Locate the softener tank and brine tank close to a drain where the system will be installed. The surface should be clean and level. (b) Perform all plumbing according to local plumbing codes. Use a 1/2” minimum pipe or tubing size for the drain line. Use a 3/4” pipe or tubing for backwash flow rates that exceed 7 gpm or length that exceeds 20ft (6m). (c) Only use Teflon tape on the drain fitting.
Installation Instructions (5) General Valve Installation (a) Installation: i. Hold the knob or use a bypass tool to rotate the knobs. ii. Water supply will be bypassed when the knobs are horizontal. iii. It is in the status of service when knobs are in the vertical direction. iv. When the bypass is in the status of service, it is available to take raw water and filter water sample for testing at water taking port on both sides of the bypass. v.
Programming the Central Water Filtration System (1) Button Configuration Key Pad Configuration • MENU This function is to enter the basic set up information required at the time of installation. • SET / REGEN This function is to initiate an immediate or delayed manual regeneration. • DOWN / UP These buttons are used to increase or decrease the value of the settings while in the programming mode. (2) Main Display "16:26" is the current time "Dec.
Programming the Central Water Filtration System "07/07" is the number of days remaining before regeneration, The estimated number of days until the next regeneration will occur, (currently set to regenerate once every 7 days; for example, "02/07" means to regenerate once every 7 days and enter the regeneration mode after 2 days) "02:00" is the current setting for regeneration time (3) Function Key Description (a) "MENU" Press the key for 3 seconds in the standby mode to unlock.
Programming the Central Water Filtration System (b) During the menu setting process, if there is no operation within 1 minute, the system will automatically return to the standby state. (c) In the standby state, if there is no operation within 3 minutes, the system will automatically lock, and the display can be processed after unlocking. (d) The regeneration mode is only a timer type. You cannot click to enter the setting.
Care of Your Central Water Filtration System The product can be used frequently after the installation and commissioning are completed. Under the condition of uninterrupted power supply, the user does not need to perform other operations on the machine. Regular replacement of filter materials under standard municipal water supply conditions, the service life of activated carbon is 6 months, and the service life of KDF filter media is 12 months.
Troubleshooting ISSUE POSSIBLE CAUSE POSSIBLE SOLUTION Unit fails to initiate a regeneration cycle No power supply Check electrical service, fuse, etc. Power failure Reset time of day. Low water pressure Iron or scale builds up in line Clean pipes. feeding unit Iron build up inside valve or tank Control valve without display Clean control and add resin cleaner to clean bed. Increase regeneration frequency. Remove piston and clean control valve.
Troubleshooting Need help troubleshooting? If you have any questions, or there are missing parts or damage, please call 1-678-261-7611 or visit www.ispringfilter.