TC-750PD1 TC-750PD1 Switching Power Supply ( 750W PS2 ATX12V ) SPECIFICATION Revision: 1.0 727 , . Phillips Drive City of Industry. CA 91748. USA http:// www.Xeal.com.
1.0 INPUT: 1.1 VOLTAGE 1.2 FREQUENCY 1.3 CURRENT 1.4 INRUSH CURRENT 1.5 POWER EFFICIENCY 1.6 LEAKAGE CURRENT 1.7 POWER FACTOR 2.0 OUTPUT: 2.1 REMOTE ON/OFF 2.2 HOLD-UP TIME 2.3 POWER GOOD DELAY 2.4 POWER FAIL DELAY 2.5 TURN-ON DELAY TIME 2.6 TRANSIENT OVERSHOOT 2.7 RISE TIME 3.0 PROTECTION: 3.1 OVER CURRENT PROTECTION 3.2 OVER VOLTAGE PROTECTION 3.3 SHORT PROTECTION 4.0 ENVIRONMENT: 4.1 OPERATING TEMP 4.2 STORAGE TEMP 4.3 OPERATING HUMIDITY 4.4 STORAGE HUMIDITY 4.5 OPERATING ALTITUDE 4.
5.0 HI-POT: 5.1 PRIMARY TO SECONDARY 5.2 INSULATION RESISTANCE 6.0 CE REQUIREMENTS: 6.1 CONDUTED EMI 6.2 SAFETY STANDARDS 6.3 HARMONIC 7.
1.0 INPUT: 1.1 VOLTAGE MINIMUM NOMINAL MAXIMUM UNITS 90 100~240 264 Vrms 1.2 FREQUENCY 47Hz ~ 63Hz 1.3 CURRENT 115Vac / 10.0A max. 230Vac / 5A max. 1.4 INRUSH CURRENT 55A max. when AC input 115Vac at 250C cold start. 0 110A max. when AC input 230Vac at 25 C cold start. 1.5 POWER EFFICIENCY 80% (min.) at full load(typical) and 115Vac input. 1.6 LEAKAGE CURRENT 3.5mA max. 1.7 POWER FACTOR PF > 0.9 2.0 OUTPUT: Voltage Ϡ +5V +3.3V +12V 1 +12V 2 +12V 3 +12V 4 -12V +5Vsb Max load 28.0A 30.
ϠϠ LOAD REGULATION TEST TABLE +5V +3.3V +12V1 +12V2 +12V3 +12V4 -12V +5Vsb LOAD1 2.0A 0.5A 1.0A 1.0A 1.0A 1.0A 0.0A 0.0A LOAD2 6.0A 4.0A 1.0A 1.0A 1.0A 1.0A 0.0A 0.5A LOAD3 16.0A 30.0A 2.5A 2.5A 3.0A 3.0A 0.3A 1.0A LOAD4 28.0A 13.0A 8.5A 9.0A 10.0A 10.0A 0.3A 1.0A LOAD5 7.0A 6.0A 13.0A 13.0A 14.0A 14.0A 0.5A 1.5A LOAD6 28.0A 0.5A 11.0A 12.0A 13.0A 13.0A 0.5A 2.0A LOAD7 4.0A 3.0A 14.0A 14.0A 13.0A 13.0A 0.8A 2.5A LOAD8 2.0A 30.
+5V 1000uF +3.3V 1000uF +12V1 2200uF +12V2 2200uF +12V3 2200uF +12V4 2200uF -12V NA +5Vsb 1uF 2.7 RISE TIME 20ms max at full load. 3.0 PROTECTION: When OCP, OVP or short protection is triggered, the main outputs will be latched off. The main outputs can be reset by cycling the DC remote on/off or AC power. +5Vsb output is auto recovery when fault condition removed. 3.1 OVER CURRENT PROTECTION +5V output: 55A max. +3.3V output: 55A max. +12V1~12V4 output: 35A max. 3.2 OVER VOLTAGE PROTECTION +3.
5.0 HI-POT:( Input/Output isolation) 5.1 PRIMARY TO SECONDARY 3535Vdc for 3 seconds 5.2 INSULATION RESISTANCE Primary to earth ground 500Vdc, 50M ohms Min. 6.0 CE REQUIREMENTS 6.1 CONDUCTED EMI 1. MEET FCCΚ!Class B 2. MEET CISPR 22Κ!Class B 3. MEET BSMIΚ!Class B 6.2 SAFETY STANDARDS 1. MEET CUL (UL 60950) 2. MEET TUV EN60950 3. MEET CB (IEC 950) ! 4. MEET CE 5. MEET CCC 6.3 HARMONIC MEET IEC1000-3-2, Class D 7.