Workshop Manual

6E–50
6VE1 3.5L ENGINE DRIVEABILITY AND EMISSIONS
10.Push “Reset” soft key.
060RY00098
11.Select F2: O2-Loop status.
060R200071
12.This test is check the “Closed Loop Status”
performance.
13.Push “Open Loop” or “Closed Loop” soft key.
060RY00099
14.Control O2-Loop and check data list.
15.If data list changes, the O2-Loop is normal.
Instruments Test
This test is conducted check Instruments for proper
operation.
Tech 2 must be used for this test.
Test Procedure:
1.Connect Tech 2 to the vehicle DLC.
2.Ignition SW is “On”.
3.Select F3: Miscellaneous Test in the Application
Menu.
060R100078