Workshop Manual

1A–90
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Check of Auto Function
No
Item
Procedure
Criteria
No
.
Item
Condition Operation
Criteria
AUTO display highlighted on
display panel.
Cold air discharge.
Set temperature to
18
°
C (65
°
F)
VENT mode.
18 C
(65 F)
.
Intake switch LED on.
Fan speed bar graph display at
MAX6dash;HI
A/C switch LED on.
1 Automatic operation Auto-switch ON
Gradually increase
the temperature
setting from 18°C
(65°F) to 31.5°C
(89°F).
Temperature of air discharge
increases with increase in setting
temperature.
Air discharge volume changes.
Panel display shows VENT,
BI–LEVEL, FOOT, or DEF/FOOT.
Hot air discharge.
A/C bar graph display disappears.
Set temperature to
32°C (90°F)
Foot mode.
32°C (90°F).
Intake LED switch off.
Fan speed bar graph display at
MAX-HI
A/C switch LED on.