Chart D: Fan Does Not Stop
Step Action Value(s) Yes No
1 1. Disconnect the max high relay, the power transistor
connector C–34 and the auto A/C control unit
connector I–20.
2. Turn on the ignition switch.
Does the blower motor stop?
Go to
Step 3
Go to
Step 2
2 Repair a short circuit between connector No.C36–2
and No.C35–5, No.C36–2 and No.C34–1, or
No.C36–2 and I20–17.
Is the action complete?
Verify repair
3 Is the max high relay normal? (Refer to the
later section
on “individual inspection”.
)
Go to
Step 4
Replace the
relay
4 Reinstall the max high relay.
Does the blower motor start operating?
Go to
Step 6
Go to
Step 5
5 Repair a short circuit between connector No.C35–4
and No.I19–2.
Is the action complete?
Go to
Step 4
6 Is the power transistor normal? (Refer to the
later
section on “individual inspection”.
)
Go to
Step 7
Replace the
power
transistor
7 Reinstall the power transistor.
Does the blower motor start operating?
Replace the
auto A/C
control unit