Workshop Manual

1A–32
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Repair Of Refrigerant Leaks
Refrigerant Line Connections
Install new O-rings, if required. When disconnecting or
connecting lines, use two wrenches to prevent the
connecting portion from twisting or becoming damaged.
852R200001
When connecting the refrigerant line at a block joint,
securely insert the projecting portion of the joint portion
into the connecting hole on the unit side and secure with a
bolt. Apply the specified compressor oil to the O-rings
prior to connecting.
CAUTION: Compressor (PAG) oil to be used varies
according to the compressor model. Be sure to apply
oil specified for the model of compressor.
850RW002
O-rings (2) must be fitted in the groove (1) of refrigerant
line.
850RW003
Insert the nut into the union.
First, tighten the nut by hand as much as possible, then
tighten the nut to the specified torque.
850RW004