Workshop Manual

5B–3
ANTI–LOCK BRAKE SYSTEM
4.Remove harness connector.
5.Remove EHCU ASM.
6.Remove EHCU.
Disassembled View
350RW025
Legend
(1) Fixing Bolts
(2) Coil Integrated Module
(3) Hydraulic Unit (H/U)
Disassembly
1.Remove fixing bolts from EHCU.
2.Remove coil integrated module from hydraulic unit.
Reassembly
To reassembly, follow the disassembly steps in the
reverse order, noting the following points:
Torque
Fixing bolts: 4.4 N·m (39 lb in)
Installation
To install, follow the removal steps in the reverse order,
noting the following points:
Torque
Hydraulic unit fixing nuts : 22 N·m (16 lb ft)
Ground cable : 14 N·m (10 lb ft)
Brake pipe (joint bolts) : 16 N·m (12 lb ft)
B After installing the hydraulic unit, bleed brakes
completely. See