Workshop Manual
1A–48
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
B Lift to remove the upper case.
874R200007
9.Remove evaporator core.
874R200008
10.Remove expansion valve.
B Tear off the insulator carefully.
B Remove the sensor fixing clip.
B Use a back-up wrench when disconnecting all
refrigerant pipes.
Installation
To install, follow the removal steps in the reverse order,
noting the following points:
1.The sensor is installed on the core with the clip.
2.The sensor must not interfere with the evaporator
core.
3.When installing the new evaporator core, install the
duct sensor (2) to the evaporator core (1) specified
position with the clip in the illustration.
874RY00016
4.O-rings cannot be reused. Always replace with new
ones.
5.Be sure to apply new compressor oil to the O-rings
when connecting lines.
6.Be sure to install the sensor and the insulator on the
place where they were before.
7.To install a new evaporator core, add 50cc (1.7 fl. oz.)
of new compressor oil to the new core.
8.Tighten the refrigerant lines to the specified torque.
Refer to
Main Data and Specifications for Torque
Specifications in this section.
9.Apply an adhesive to the parting face of the lining
when assembling the evaporator assembly.