Workshop Manual
1A–56
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
4.Remove snap ring (1) by using snap ring pliers.
871RY00029
5.Remove pulley assembly by using pulley puller pilot
J-38424 (2), pulley puller J-8433 (1) and pulley puller
leg J-24092-2 (3).
871RY00033
6.Loosen screw and disconnect the field coil wire
connector.
871RY00030
7.Loosen three screws and remove the field coil.
871RY00034