User's Manual

Installing 100G ERT Module on Actaris
10. Turn the index drive dog so it fits into the extension driver. The hole in the center of
the adapter plate should fit comfortably around the extension driver and the rivets in
the 100G ERT Module should fit into the holes in the adapter plate.
11. Place the index cover over the index assembly. The transparent section of the cover
needs to be on the same side as the index dials so the meter readers can read the dials
clearly.
12. Align the four holes in the index cover with the holes located in each corner of the
adapter plate and install the cover screws.
13. Turn each screw 1/4 to 1/2 turn after it contacts the cover.
14. Place the tamper seals into the front right and back left of the screw holes of the index
cover.
15. Install tamper seals over the screws and press them into place with an 11/32 nut
driver, or some other blunt tool. The tamper seals should not protrude above the index
cover screw holes.
Natural Gas Solutions 100G Installation Guide 71