Chapter 4 Actaris Meter Installation
38 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
Materials Supplied By You
The following tools are required to install, initialize, and check the 100G ERT Module on
the meter.
Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten
index and index-cover screws.
Side-cutting plier/wire snips Used for cutting wire seals, if necessary.
Small putty knife Used to remove all traces of old gaskets from the meter.
Meter seals, wire seals, and seal press Used to secure the meter from tampering, if
necessary.
11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs
over screw holes.
Replacement screws Used to mount 100G ERT Module assembly to meter and
index to module assembly backplates.
FC200SR with EndPoint-Link or EndPoint-Link Pro software Used to program
and check ERT assembly.
Replacement Screws
Replacement screws used in this procedure include:
For mounting 100G ERT Module assemblies on meters:
Use 10 - 24 x 5/8-inch slotted, Fillister head screws.
For mounting indexes on 100G ERT Module backplates:
Use 10 - 24 x 1/4-inch slotted, round head screws.
Pre-installation Preparations
Before installing the 100G ERT Module on a meter, verify:
All Itron 100G ERT Module gas modules are compatible with your brand of gas
meter.
See the Meter Compatibility List for compatible meter model numbers for the
100G ERT Module