User's Manual

Elster American and Itron Commercial Meter Installation
To enable enhanced security and for more complete programming information, see the Field Deployment
Manager Endpoint Tools Mobile Application Guide (TDC-0934).
FC200SR FC300 with SRead 900MHz Belt Clip Radio
Caution You must program the 100G commercial ERT module before use.
Take note of the index drive rate shown on the index. The ERT is programmed based on the drive rate. Elster
American commercial meter index drive rates may be 5-, 10- or 100 cubic feet. The index shown has a 10-
cubic foot drive rate.
To program the commercial gas ERT module
1. Program the index drive rate into the 100G using the endpoint programming device.
2. For all programming and "Check Endpoint" operations, hold the handheld as close to vertical as possible.
For best success, keep the handheld programmer within 6 feet of the target endpoint.
3. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode,
Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming
parameters are based on the configuration file loaded into the endpoint programming device. During
programming, the 100G is set to the nearest 100 cubic feet; the last two digits (tens and units) are
programmed as zeros (0). After programming is complete, the ERT assembly will read to the nearest cubic
foot.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 61