User's Manual

Elster American and Itron Commercial Meter Installation
Itron Adapter Kit Materials
Itron Part Number (Kit
Component)
Tamper seals
017167
Extension driver
550417
Optional Installation Materials
(available from Itron)
Itron Part Number
Index cover
80006001
Commercial index
Various
Index mounting screws
dial index
odometer index
010040
090071
To remove the index cover
1. Place a slotted screwdriver over one of the red security seal covering the index cover mounting screws.
2. Push on the handle-end of the screwdriver to drive the slotted end into the security seal.
3. Pry the broken security seal out of the index screw mounting cup. Be careful not to damage the index
cover. Remove the second security seal.
4. Remove the index cover mounting screws with the slotted screwdriver.
5. The index cover has either a room temperature vulcanizing (RTV) or cork gasket. Carefully remove the
index cover and inspect the cover for wear or damage to the RTV (silicone) or cork gasket.
Caution If the RTV silicone gasket is damaged during removal or shows signs of degradation, you must
replace it with a new index cover from Itron.
6. Set the index cover aside. The index will be reinstalled later in the installation.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 66