To remove the index and index mounting bracket
1. Remove the two screws holding the index bracket to the meter.
2. To remove a dial index, loosen the two screws holding the index to the index bracket in an alternating
pattern:
Loosen the right index mounting screw two turns.
Loosen the left index mounting screw two turns.
Loosen the right and left index mounting screws until you can slide the index to the left and away
from the index mounting screws and bracket.
3. To remove an odometer index, remove the two screws holding the index to the index bracket. Temporarily
store the index and index mounting screws in a safe location.
To install the index on the index mounting bracket
1. If the original dial index mounting screws cannot be reused, remove them from the index mounting
bracket and recycle or discard.