User's Manual

Elster American and Itron Commercial Meter Installation
2. Insert the dial index mounting screws (part number 010040) in the index mounting bracket. Tighten the
index mounting screws just enough to secure them in the index mounting bracket.
3. Slide the index mounting legs (1) all the way to the right over the index screws. The mounting bracket
drive dog must engage with the index wriggler (2).
Warning Failure to properly engage the mounting bracket drive dog and index wriggler may cause
binding and meter failure.
4. Tighten the index mounting screws in an alternating pattern.
Warning Verify the index is correctly positioned all the way to the right on the index mounting screws
before you tighten the index mounting screws. Failure to properly mount the index on the index mounting
screws may cause binding and meter failure.
5. Tighten (torque) the index mounting screws to 3 - 6 inch-pounds.
To install the index on the index mounting bracket
1. If the original odometer index mounting screws cannot be reused, recycle or discard them. Use new
odometer index mounting screws (part number 090071).
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 68