User's Manual

Elster American and Itron Commercial Meter Installation
2. Align the mounting bracket drive dog with the index wriggler.
Warning Failure to properly engage the mounting bracket drive dog and index wriggler may cause
binding and meter failure.
3. Insert the odometer index mounting screws through the index mounting hole and into the mounting
bracket.
4. Tighten the index mounting screws in an alternating pattern. Tighten (torque) the index mounting screws
to 3 - 6 inch-pounds.
Programming the Commercial Gas ERT Module Assembly
Program commercial 100G, 100G DL, 100G DLN, or 100G DLT ERT modules using:
An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or
A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or
higher
or
A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 69
Proprietary and Confidential