User's Manual

Elster American and Itron Commercial Meter Installation
5. Secure with the four mounting screws from the adapter kit. Tighten the mounting screws in a diagonal
alternating pattern.
Insert the first screw and tighten enough to hold the index in place.
Insert the second screw and tighten two to three turns.
Insert the third mounting screw and tighten two to three turns.
Insert the fourth mounting screw and tighten.
6. Tighten the first, third and second screw using an alternating tightening pattern. Turn each screw 1/4 to
1/2 turn after the screw contacts the index cover. Tighten each index mounting screw evenly. If you have
access to a torque-driver, tighten mounting screws to 20 to 25-inch pounds.
7. Insert tamper seals in the tamper seal cups on the index cover and press into place with an 11/32 nut driver
or similar blunt tool.
This completes installation of the commercial AMR module on the Itron commercial meter.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 74