User's Manual

Sensus Commercial Meter Installation
To remove the index from the meter
1. Remove any tamper seals (or wire seals) from the index cover and remove the index cover mounting
screws. You will reinstall it later in these instructions.
2. Remove the index screws from the meter. Set the index cover aside where it will not be damaged or fill
with dirt, rain or snow. You will re-install the index later in this procedure.
Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover
materials. Do not leave materials on customer premises.
Programming the Commercial Gas ERT Module Assembly
Program commercial 100G, 100G Datalogging, 100G DLN, or 100G DLT ERT modules using:
An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or
A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or
higher
or
A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 76
Proprietary and Confidential