User's Manual

Sensus Commercial Meter Installation
Mounting a 100G Gas ERT Module on a Rockwell 750 meter
with an Aluminum BOX Direct Reading (VDR)
Installing the 100G series commercial gas ERT module on a Rockwell commercial meter with an aluminum
box direct reading (VDR) index requires two Itron SCR-0062-001 mounting screws (see Installation
Prerequisites on page 14). The mounting screws must be purchased separately.
To remove the index from the meter
1. Remove tamper seals and screws from the top of the aluminum box direct reading index. Set the cover and
screws aside. You will use them later in the installation.
2. Remove the screws holding the aluminum box to the meter.
3. Carefully remove the aluminum box and set it aside. You will use it later in this installation.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 81
Proprietary and Confidential