GE Oil & Gas Dresser Commercial Rotary Meter Installation
For 5C15 and 8C15 Rotary Meters, program as 4 dial, 2 cubic foot index. For all other residential 100G series
gas ERT modules, refer to B3, LMMA, and S3A CTR/TC GE Dresser Series Register Settings and Direct
Drive Programming Information on page 88.
To program the 100G ERT module
Program the meter drive rate into the commercial ERT module using the endpoint programming device. For
all programming and Check Endpoint operations, hold the handheld programmer as close to vertical as
possible. For best success, keep the handheld programmer within 6 feet of the target ERT module. Verify you
have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read
Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file
loaded into the endpoint programming device.
During programming, the commercial ERT module is set to the nearest 100 cubic feet; the last two digits (tens
and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read
to the nearest cubic foot.
B3, LMMA, and S3A CTR/TC GE Dresser Series Register
Settings and Direct Drive Programming Information
Use the information in the following tables to program GE Dresser Series B3, LMMA, and S3A non-
compensated counter (CTR) and temperature compensated (TC) registers. Reference the 100G Gas ERT
Module Meter Compatibility List to confirm compatibility.
Settings for Series B3 Registers
Settings for LMMA Registers
Model
Meter size
Settings
Model
Meter Size
Settings
CTR 8C-15C and 2M-11M
16M-56M
Number of dials: 5
Drive rate: 10
PCOMP factor: NONE
Number of dials: 6
Drive rate: 100
PCOMP factor: NONE
CTR 1.5M-11M
16M
Number of dials: 5
Drive rate: 10
PCOMP factor: NONE
Number of dials: 6
Drive rate: 100
PCOMP factor: NONE
TC 8C-15C and 2M-11M
16M
Number of dials: 5
Drive rate: 100
PCOMP factor: NONE
Number of dials: 6
Drive rate: 1000
PCOMP factor: NONE
TC 1.5M-11M
16M
Number of dials: 5
Drive rate: 50
PCOMP factor: NONE
Number of dials: 6
Drive rate: 500
PCOMP factor: NONE
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 88