User's Manual

GE Oil & Gas Dresser Commercial Rotary Meter Installation
Installing the Commercial Gas ERT Module Assembly on a GE
Dresser Rotary Meter with an Instrument Drive
The information in this section guides you through the installation of the commercial gas ERT on GE Dresser
rotary meters.
Note This installation procedure requires a GE Dresser rotary gas meter with an instrument
drive. These instructions show an Elster American commercial ERT module. The installation
procedure is identical for the Sensus commercial ERT module.
100G Elster American
Commercial Gas ERT Module
100G Sensus
Commercial Gas ERT Module
Installation requires the following items:
One index mounting plate (if applicable)
Gasket and drive cover kit (if applicable)
An Elster American Meter or Sensus commercial ERT module
A flat, slot-drive screwdriver
Programming the Commercial Gas ERT Module
Program 100G, 100G DL, 100G DLN, or 100G DLT commercial ERT modules using:
An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher
or
A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or
higher
or
A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 91
Proprietary and Confidential