User's Manual

GE Oil & Gas Dresser Commercial Rotary Meter Installation
The 100G DLS ERT modules support enhanced security with the Itron Security Manager. Enabling
command or enhanced security requires additional programming. Program the 100G DLS ERT modules
using:
An FC200SR handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher
or
An FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 3.3
or higher
or
A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 3.3 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
To enable enhanced security and for more complete programming information, see the Field Deployment
Manager Endpoint Tools Mobile Application Guide (TDC-0934).
FC200SR FC300 900MHz Belt Clip Radio
Caution You must program the 100G ERT module before use.
The ERT module is programmed based on the meter's drive rate. See B3, LMMA, and S3A CD/TD GE
Dresser Meter Drive Rates.
Program the meter drive rate into the 100G commercial gas ERT module using the endpoint programming
device. For all programming and Check Endpoint operations, hold the handheld programmer as close to
vertical as possible. For best success, keep the handheld programmer within 6 feet of the target ERT module.
Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to
Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration
file loaded into the endpoint programming device.
During programming, the 100G Datalogging FN commercial gas ERT module is set to the nearest 100 cubic
feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT
module assembly will read to the nearest cubic foot.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 92