User's Manual

GE Oil & Gas Dresser Commercial Rotary Meter Installation
3. Verify the ERT wriggler and drive dog shaft are engaged by turning the commercial ERT module
wriggler. When properly engaged, you will feel resistance.
4. Place the customer-supplied index mounting plate on the ERT and install the four mounting screws. Do
not disturb the shaft alignment.
5. Install the four ERT module mounting screws (supplied with the commercial ERT). Tighten mounting
screws in an alternating, diagonal pattern. Tighten each ERT module mounting screw evenly.
Turn each screw 1/4 to 1/2 turn after it contacts the cover.
Torque to 20 - 25 inch-pounds.
6. Insert new utility-approved wire seals and crimp (if required).
Note To mount an index and index cover on a rotary meter without an accessory odometer unit, remove
the domed cover and reference To attach the index and cover assembly on the meter on page 64.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 95
Proprietary and Confidential