User's Manual

Romet Commercial Rotary Meter Installation
The 100G DLS ERT modules support enhanced security with the Itron Security Manager. Enabling
command or enhanced security requires additional programming. Program the 100G DLS ERT modules
using:
An FC200SR handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher
or
An FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 3.3
or higher
or
A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 3.3 or higher and a
customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or
Bluetooth.
To enable enhanced security and for more complete programming information, see the Field Deployment
Manager Endpoint Tools Mobile Application Guide (TDC-0934).
FC200SR FC300 with SRead 900MHz Belt Clip Radio
Caution You must program the 100G ERT module before use.
For 5C15 and 8C15 Rotary Meters, program as 4 dial, 2 cubic foot index. For all other residential 100G series
gas ERT modules, refer to B3, LMMA, and S3A CTR/TC GE Dresser Series Register Settings and Direct
Drive Programming Information on page 88.
To program the 100G ERT module
Program the meter drive rate into the commercial ERT module using the endpoint programming device. For
all programming and Check Endpoint operations, hold the handheld programmer as close to vertical as
possible. For best success, keep the handheld programmer within 6 feet of the target ERT module. Verify you
have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read
Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file
loaded into the endpoint programming device.
During programming, the commercial ERT module is set to the nearest 100 cubic feet; the last two digits (tens
and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read
to the nearest cubic foot.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 98
Proprietary and Confidential