User's Manual

Sensus Meter Installation
To enable enhanced security and for more complete programming information, see the Field Deployment
Manager Endpoint Tools Mobile Application Guide (TDC-0934).
FC200SR FC300 with SRead 900MHz Belt Clip Radio
Caution You must program the 100G ERT module before use.
The ERT is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower
dial on the index. Sensus meter index drive rates are typically 2-cubic feet.
To program the ERT module assembly
1. Program the meter drive rate into the 100G series gas ERT module using the endpoint programming
device.
2. For all programming and Check Endpoint operations, hold the handheld programmer as close to vertical as
possible. For optimal results, keep the handheld programmer within 6 feet of the target ERT module.
3. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode,
Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application.
4. Programming parameters are based on the configuration file loaded into the ERT module programming
device. During programming, the 100G is set to the nearest 100 cubic feet; the last two digits (tens and
units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read
to the nearest cubic foot.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 28
Proprietary and Confidential