Tip The following conditions ensure proper engagement of the ERT module to the meter:
The ERT module fits flush against the meter body--there are no gaps between the ERT gasket and the
meter body.
The ERT module mounting holes align with the index cover mounting holes on the meter body.
The meter test dial moves in relation to gas flowing through the meter.
9. Place a new tamper seal in the tamper seal cups surrounding the two mounting screws. Press the new
tamper seals into place using an 11/32-inch nut driver or similar blunt tool.
10. Complete any necessary paperwork and properly dispose excess installation materials and scrap from the
customer premises.
100G ERT module installation on the Itron meter is complete.