User's Manual

Itron Meter Installation
Attaching the ERT Module Assembly to Sprague Flat-faced
Meters
100G ERT module installation on a flat-faced Sprague meter requires the Itron Adapter Plate Kit (CFG-0015-
001).
Itron Adapter Plate Kit (CFG-0015-001)
1 Adapter Shim Plate
2 Index Cover Mounting Screws
3 Drive Dog
4 Adapter Plate Mounting Screws
To attach the ERT module assembly to the flat-faced Sprague meter
1. Verify the kit includes the materials listed in the Itron Adapter Plate Kit table.
Warning The adapter plate must fit flush against the meter face. Some older Sprague meters are not
compatible with the adapter plate. The following examples illustrate the potential obstruction (problem)
areas between the adapter plate and meter. Failure to mount the adapter plate flush on the front of a meter
could result in a binding condition and lead to poor registration or meter failure.
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 39