User's Manual Part 2

Attaching the 100G Datalogging Gas Endpoi
nt Assembly to the Itron/Actaris Meter
100G Datalogging Installation Guide - Direct Mount 37
3. Endpoint to meter mounting screws must be installed in an alternating fashion. Use
the original mounting screws if they were the correct size and not corroded. If the
original screws were discarded, use the correct replacement screws (see Installation
Prerequisites on page 8.) Insert the right index cover mounting screw and tighten the
screw enough to hold it in place. Do not completely tighten. Install the left index
cover mounting screw and tighten to a snug fit. Finish by tightening the right
mounting screw to a snug fit. Each mounting screw must be tightened evenly.
Important Meter manufacturers should torque the mounting screws 15 to 20
inch-pounds.
1. Place a new tamper seal over the two screws in the tamper seal cups. Press the new
tamper seals into place using the 11/32-inch nut driver (or similar blunt tool).
2. Complete any necessary paperwork and properly dispose excess installation materials
and scrap from the customer premises.