User's Manual Part 2

Chapter 4 Itron/Actaris Meter Installation
40 100G Datalogging Installation Guide - Direct Mount
Warning The Adapter Shim Plate must fit flush against the meter face. Some
older Schlumberger/Sprague meters are not compatible with the adapter plate.
The following examples illustrate the potential obstruction (problem) areas
between the adapter plate and meter. Failure to mount adapter plate flush on
the front of a meter could result in a binding condition and lead to poor
registration or meter failure.
2. Remove the drive dog from the flat-faced Itron/Actaris meter. Replace it with the
extended drive dog included in the kit. Hand-tighten to snug.
Warning The meter drive dog shaft is surrounded by a gasket. A gas leak could
result if the gasket is damaged. Do not use a tool to install or tighten the new drive
dog. Hand-tighten only.