User's Manual Part 2

Attaching the 100G Datalogging Gas Endpoint Assembly to the Sensus Meter
100G Datalogging Installation Guide - Direct Mount 27
3. Read the 100G Datalogging Gas Endpoint using the FC200SR.
If the read result is higher than the number programmed in Step 1, the 100G
Datalogging Gas Endpoint is counting correctly.
If the read result is not higher than the number programmed in Step 1, replace
the 100G Datalogging Gas Endpoint.
Attaching the 100G Datalogging Gas Endpoint Assembly to
the Sensus Meter
After 100G Datalogging Gas Endpoint programming is complete, attach the endpoint
assembly to the Sensus meter.
To Attach the 100G Datalogging Gas Endpoint
1. Gently place the ERT module assembly against the front of the meter at angle.
Endpoint-to-meter mounting screws are installed and tightened in an alternating
fashion. Align the top right mounting screw-hole on the meter with the top right
screw-hole on the endpoint. Insert the top-right cover mounting screw and tighten the
screw enough to hold it in place. Do not completely tighten. Rotate the Endpoint
assembly counterclockwise until the remaining three endpoint screw holes line up
with the holes in the meter. Use the original mounting screws if they were the correct
size and not corroded. If the original screws were discarded, use the correct
replacement screws (see Installation Prerequisites on page 8.)