User's Manual Part 3

Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris Commercial Meter
100G Datalogging Installation Guide - Direct Mount 69
3. Inlet lettering on the 100G Datalogging Commercial Gas Endpoint must line up with
Inlet lettering on the meter. Slowly lower the endpoint on the Itron-Actaris
Commercial meter aligning the drive dog and wriggler. The endpoint housing should
rest on the top of the meter without gaps.
Warning Do not press down on the 100G Datalogging Gas Endpoint if a gap
exists between the endpoint and the meter.
A gap may be caused by misalignment of the endpoint wriggler and meter
wriggler's drive teeth. Pushing down on the endpoint could damage the
endpoint wriggler or meter drive teeth. To eliminate a gap, remove the 100G
Datalogging Gas Endpoint and repeat steps 2 and 3.
To Attach the Index on the Itron-Actaris Commercial Meter
1. Place the Itron-Actaris adapter plate on the 100G Datalogging Commercial Gas
Endpoint with the two small screw holes in the adapter plate to the back of the meter.
Meter Front