User's Manual Part 3

Programming the 100G Data
logging Gas Endpoint
100G Datalogging Installation Guide - Direct Mount 75
Take note of the index drive rate shown on the index. The endpoint is programmed based on
the drive rate. Sensus/Rockwell commercial meter index drive rates may be 5-, 10- or 100-
cubic feet. The seven-dial index shown is a 100-cubic feet drive rate.
To Program the 100G Datalogging Commercial Gas Endpoint
1. Program the index drive rate into the commercial endpoint using the FC200SR. For all
programming and "Check Endpoint" operations, hold the FC200SR as close to vertical
as possible. For best success, keep the FC200SR within 6 feet of the target endpoint.
Verify you have the correct programming mode (Fixed Network Mode,
Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your
application. Programming parameters are based on the mode defined by your system
administrator.
During programming, the 100G Datalogging Gas Endpoint is set to the nearest 100
cubic feet; the last two digits (tens and units) are programmed as zeros (0). After
programming is complete, the endpoint assembly will read to the nearest cubic foot.
2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the
index drive rate. This verifies the endpoint is counting properly.
Caution Do not turn the drive wriggler faster than one turn per second.
3. Read the 100G Datalogging Gas Endpoint using the FC200SR.
If the read result is higher than the number programmed in Step 1, the 100G
Datalogging Gas Endpoint is counting correctly.
If the read result is not higher than the number programmed in Step 1, replace
the 100G Datalogging Gas Endpoint.