User's Manual Part 3

Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commer
cial Diaphragm Meter
100G Datalogging Installation Guide - Direct Mount 77
3. Verify the bottom of the 100G Datalogging Commercial Gas Endpoint and the top of
the meter meet. The endpoint housing should rest on top of the meter without gaps.
Warning Do not press down on the 100G Datalogging Commercial Gas
Endpoint if a gap exists between the endpoint and the meter.
A gap may be caused by misalignment of the endpoint wriggler and meter
wriggler's drive teeth. Pushing down on the endpoint could damage the
endpoint wriggler or meter drive teeth. To eliminate a gap, slowly turn the 100G
Datalogging Commercial Gas Endpoint's upper wriggler back and forth until the
endpoint aligns with the meter's drive teeth.
4. Align the 100G Datalogging Commercial Gas Endpoint with the index mounting
holes. Verify the index drive dog intersects with the endpoint's wriggler. Install the
endpoint mounting screws (SCR-0062-003 see Installation Prerequisites on page 8 for
screw information). Turn each screw 1/4 to 1/2 turn after it contacts the
index/endpoint assembly.