User's Manual Part 3

Removing the Index/ Index Assembly from the Meter
100G Datalogging Installation Guide - Direct Mount 59
To Remove the Index Assembly
1. Remove any tamper seals (1) (or wire seals) from the index cover and mounting plate
screws (2). Set the index/cover assembly aside. You will re-install it later in these
instructions.
2. Remove the index cover screws from the meter. Verify screws are 1/2" long and are
not corroded. If the screws are the correct length and are not corroded, keep them to
re-install the 100G Datalogging Gas Endpoint assembly later in this procedure. If the
screws are damaged or not the correct length, discard.
Note Properly dispose all unused screws, old index covers, gaskets, tamper seals,
and other leftover materials. Do not leave materials on customer premises.