User's Manual Part 3

Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter
100G Datalogging Installation Guide - Direct Mount 91
Programming the 100G Datalogging Commercial Gas
Endpoint Assembly
The 100G Datalogging Commercial Gas Endpoint must be programmed with the
FC200SR handheld computer loaded with EndPoint-Link
®
or Point-Link Pro
®
software
version 5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming
Guide (TDC-0744) for more complete programming information.
Caution The 100G Datalogging Commercial Gas Endpoint must be programmed
before use. Follow the steps in this section to properly program the endpoint.
The endpoint is programmed based on the meter's drive rate. See B3, LMMA, and S3A
CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming
Information on page 93.
To Program the 100G Datalogging Commercial Gas Endpoint
1. Program the meter drive rate into the 100G Datalogging Commercial Gas Endpoint
using the FC200SR. For all programming and "Check Endpoint" operations, hold the
FC200SR as close to vertical as possible. For best success, keep the FC200SR within
6 feet of the target endpoint. Verify you have the correct programming mode (Fixed
Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode)
for your application. Programming parameters are based on the mode defined by your
system administrator.
During programming, the 100G Datalogging Commercial Gas Endpoint is set to the
nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros
(0). After programming is complete, the endpoint assembly will read to the nearest
cubic foot.