User's Manual Part 3

Installing t
he 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter
100G Datalogging Installation Guide - Direct Mount 93
B3, LMMA, and S3A CD/TD Dresser ROOTS Series Meter
Drive Rates
Use the information in the following tables to program 100G Datalogging Commercial
Endpoints installed on Dresser Roots Series B3, LMMA, and S3A Non-compensated
Counter with Instrument Drive (CD) and Temperature Compensated Counter with
Instrument Drive (TD) registers. Reference the Meter Compatibility List on page 2 to
confirm compatibility.
Warning Drive rates listed in the following tables are for commercial endpoint
programming. Do not use these settings to program residential or remote
endpoints.
B3 CD
Meter Size
B3 CD Meter
Drive Rates
8C 10
11C 10
15C 10
2M 10
3M 10
5M 10
7M 10
11M 10
16M 100
23M 100
38M 100
56M 100
B3 TD
Meter Size
B3 TD Meter
Drive Rate
8C 100
11C 100
15C 100
2M 100
3M 100
5M 100
7M 100
11M 100
16M 1000