User's Manual Part 3

Programming the 100G Datalogging Commercial Gas Endpoint
100G Datalogging Installation Guide - Direct Mount 63
2. Align the endpoint so the screw holes line up with the meter's top screw holes.
Carefully lower the endpoint on the meter with the wriggler notches lining up with the
meter's wriggler teeth.
Warning The INLET label on the 100G Datalogging Commercial Gas Endpoint
must line up with the INLET label on the meter case.
3. Verify the bottom of the endpoint and the top of the meter meet. The endpoint housing
should rest on top of the meter without gaps.
Warning Do not press down on the 100G Datalogging Commercial Gas
Endpoint if a gap exists between the endpoint and the meter.
A gap may be caused by misalignment of the endpoint wriggler and meter
wriggler's drive teeth. Pushing down on the endpoint could damage the
endpoint wriggler or meter drive teeth. To eliminate a gap, slowly turn the
endpoint's upper wriggler back and forth until the endpoint aligns with the
meter's drive teeth.