User's Manual

Diaphragm Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 56
Proprietary and Confidential
3. Remove the old gasket and any gasket residue from the meter and the index cover.
4. Use the FC200 or FC300 to read the 100G Datalogging FN remote ERT module. Record the reading for
comparison with progressive readings as installation is completed.
To install the encoder
1. Remove the magnet hub from the Encoder Installation kit ( Itron part number CFG-0081-001). Verify
there is only one magnet in the hub.
Note If there is no magnet or if there are two magnets in the magnet hub, discard the magnet hub and use
a hub with one magnet.
2. Briefly place the magnet side of the magnet hub into the curved indentation in the encoder, as shown.
3. Remove the magnet hub from the encoder and set it at least one inch away from the encoder.
4. Use the endpoint programming device to read the 100G Datalogging FN remote ERT module. If this
reading is higher than the reading taken after removing the index, the ERT module is counting and
working properly.
Note If the reading is not higher than the previous reading, the 100G Datalogging FN remote ERT
module is not reading. Repeat steps 3, 4, and 5. If the ERT module is still not counting, replace the 100G
Datalogging FN remote ERT module and perform steps 3, 4, and 5.