User's Manual

TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 66
Proprietary and Confidential
This section provides the instructions to install the 100G Datalogging FN remote ERT module with Itron
DATTUS fM2 and fM3 meters.
DATTUS fM2 DATTUS fM3
Installation Prerequisites
100G Datalogging FN remote ERT module installation to a DATTUS meter requires the following materials:
100G Datalogging FN remote ERT module compatible with the DATTUS meter (see the 100G
Datalogging FN Remote ERT Module Meter Compatibility List on page 3).
Itron DATTUS meter compatible with the 100G Datalogging FN remote ERT module.
Tools and devices to complete installation and programming (see Installation Prerequisites on page 5)
Programming the DATTUS Meter
Program the DATTUS fM2 or fM3 meter with the correct pulse width and weight. For all DATTUS type
meters, the pulse width must be set to .050 seconds.
DATTUS Meter Pulse Weight Settings
Meter type
Pulse weight in cubic feet (CF)
or cubic meter (CM)
11M or smaller
10 (CF) or 1 CM
16M or greater
100 CF or 1 CM
Installation Overview
Installing the 100G Datalogging FN remote ERT module to an DATTUS meter involves five tasks:
1. Programming the meter (see Programming the DATTUS Meter on page 66 or the Itron DATTUS
programming guide for more information).
C H A P T E R 6
DATTUS Meter Installation