User's Manual

DATTUS Meter Installation
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 69
Proprietary and Confidential
Connecting the Remote ERT Module to a DATTUS meter
The DATTUS fM2 and fM3 meters have two configurable outputs usable as pulse outputs to the 100G
Datalogging FN remote ERT module. Connecting the endpoint following the information in this section
requires a pulse output cable, installed at the Owenton, Kentucky Itron location. Pulse output cables are
available in 10-foot and 20-foot lengths. Factory-installed cables have a Binder connector on one end and six
bare wires on the opposite end.
DATTUS Meter Wiring Accessories (available from Itron, Owenton, Kentucky)
Accessory
Itron Part Number
Pulse output cable - 10 ft.
442461-009
Pulse output cable - 20 ft.
442461-010
Pulse output cable
To wire the 100G Datalogging FN remote ERT module to the DATTUS meter
Pulse Output Cable Pin Descriptions
To use Output 3
To use Output 4
Pin
Function
Wire color
ERT wire color
ERT wire color
1
Cut cable
White
Blue
2
Output 4 (+)
Black
White
3
Ground (-)
Green
Red
4
Output 3 (+)
Orange
White
5
Cut cable
Red
Blue
6
Ground (-)
Blue
Red