Connecting and Configuring the Module and Instrument
TDC
-1346-000 100T-HON Honeywell Telemetry Module Installation Guide 18
Proprietary and Confidential
The Mechanical Uncorrected Volume Switch
The 100T-HON telemetry module supports a connection to a mechanical uncorrected volume switch output
from the Honeywell Mini-Max and Mini-AT instruments. This switch output allows the 100T-HON telemetry
module to independently count the mechanically uncorrected volume, even if the instrument losses power.
To collect mechanical uncorrected volume data, the following must be true:
The instrument must have the mechanical pulse output option board installed.
The module’s mechanical pulser cable must be connected to the Honeywell instrument.
The module must be configured to use the mechanical uncorrected volume as its channel 2 data stream.
The 100T-HON telemetry module pulse counter supports a maximum of 1 pulse per second with at least 1/3
second on, and 1/3 second off.
Electronic Corrected Pulse Output
The 100T-HON telemetry module does not provide a connection to an instrument electronic corrected pulse
output. Electronic corrected volume data is collected through the serial connection.
Electronic Uncorrected Pulse Output
The 100T-HON telemetry module does not include a connection to an instrument electronic uncorrected pulse
output. Electronic uncorrected volume data is collected through the serial connection.
Alarm Switch
The 100T-HON telemetry module does not include a connection to an instrument alarm switch. The
instrument alarm data is collected through the serial connection.
Honeywell Instrument Cable Connections
The 100T-HON telemetry module cable enters the Honeywell instrument through a watertight compression
connector on the back of the instrument.
Mini-AT compression connector ERX/MiniMax compression connector
The 100T-HON telemetry module connects to the Honeywell Mini-AT, MiniMax, and ERX instruments.