User's Manual

Connecting and Configuring the Module and Instrument
TDC
-1346-000 100T-HON Honeywell Telemetry Module Installation Guide 19
Proprietary and Confidential
The 100T-HON telemetry module includes a single 5-foot cable. The cable accommodates the RS232 serial
connection or connection to the mechanical uncorrected volume.
100T-HON telemetry module to Mercury Instrument Connections
Wire Color
Wire Function
Instrument Connection
White Pulse Interface (Count Sense) Pulser Board--COM
Red Pulse Interface (Count Enable) Pusler Board - NO
Black RS232 Ground RS232 Main or Adapter Board--COM
Green RS232 Tx RS232 Main or Adapter Board--Tx
Yellow RS232 Rx RS232 Main or Adapter Board--Rx
To connect the 100T-HON telemetry module to the Mini-AT Mercury Instrument
If the 100T-HON telemetry module will be connected to the Honeywell Mini-AT, the module must have
an RS232 connection to the instrument. (Optional) The module connection to the Mini-AT may be a
mechanical uncorrected volume pulser connection.
1. RS232 Terminal Block
2. Compression Connector
3. Pulser Board