User's Manual

TDC-0951-001 100W-R and 100WP-R Datalogging Water Endpoint Installation Guide 7
Proprietary and Confidential
This chapter provides the instructions to initialize the 100W-R, connect the endpoint to water meter registers
and program the 100WP-R.
Initializing the 100W-R
To initialize the 100W-R immediately, use one of the following handheld computers running Field
Deployment Manager (FDM) version 1.0 or later.
FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
FC300 with SRead
For normal activation, connect the 100W-R to the water meter register. The endpoint polls for a register
every hour. The 100W-R automatically activates after the endpoint detects a register.
Connecting the 100W-R to a Remote Meter Register
Connect the wires from the endpoint to the register according to the following table.
100W-R Connections
Register Manufacturer
100W-R wire color
Brown (data)
Gray
(power/clock)
Yellow
(ground)
Register screw color designator
Elster AMCO Invision
R
GRN
BLK
Elster AMCO Scancoder
R
GRN
BLK
Elster AMCO evoQ4 (Q4000)
R
White
BLK
Hersey Translator
GRN
R
BLK
Badger ADE
GRN
R
BLK
Sensus ECR (all variants)
GRN
R
BLK
Sensus ICE
GRN
R
BLK
Itron (Actaris) Coder
GRN
R
BLK
Metron Famier
GRN
R
BLK
ProRead &
ProRead Auto Detect
R
BLK
GRN
Performance ETR
GRN
R
BLK
SevernTrent SM700
SmartMeter
(Sensus Protocol)
GRN
R
BLK
Neptune E-coder
R
BLK
GRN
C H A P T E R 3
Initializing, Connecting, and Programming